IT-089 DVB-T/T2 Signal Analyzer is a configuration of the IT-08 Multifunction TV Meter comprised of MB-08 Base Unit and MC-089 Removable Module. IT-089 is designed to ensure high-performance control and adjustment of television and broadcasting distribution networks as well as of separate components of such networks, or other electronic devices. The Analyzer allows measurement of DVB-T/T2 signal parameters and analog signals. IT-089 is capable to satisfy your measurement needs for high-quality operation within the range of 45 to 865 MHz.
IT-089 GENERAL FEATURES:
o Lightweight and compact handheld design
o Measurement modes:
· BER/MER mode performs measurements of DVB-T/T2 channels, indicates measurement results on a bar-graph or a constellation diagram
· SPECTRUM mode provides scanning of entire band with the span of 18, 36, or 72 MHz
· SCAN, TILT and RIPPLE modes indicate the level of all the channels present in the band (or channels according to the channel plan) on a bar-graph
o LEVEL measurements:
· for analog channels: channel level, Carrier to Noise (C/N) ratio, Video to Audio (V/A) ratio
· for digital channels: channel power, Carrier to Noise (C/N) ratio
o Measurement of reception quality parameters of digital channels:
· modulation error rate (MER)
· bit error rate before (preVBER) and after (postVBER) Viterbi decoder, and also after (postBER) Reed-Solomon decoder for DVB-T channels
· bit error rate before (preLDPC) and after (postLDPC) LDPC decoder, and also after (postBCH) BCH decoder for DVB-T2 channels
· channel carrier frequency offset from the tuning frequency
· echo measurements
o Data logger function providing storage for:
· up to 32 channel plans (with channel names). Automatic channel plan creation. Automatic search for digital channel parameters (modulation type, symbol rate)
· up to 200 measurement logs (each indicating channel levels, C/N and V/A ratios), checking the parameter compliance with the limit plan and saving comments and measurement date and time. For digital channels, channel power within bandwidth, S/N ratio, BER, and MER are measured
· up to 200 spectrum analyzer logs with 125 kHz step, adjustable scanning span and saving comments and measurement date and time. Saving up to 14 spectrum logs within the full frequency range
o Measurement of AC/DC input voltage within the range of 10 to 100 V
o External devices (amplifiers, etc.) powering over input connector
o Operation with PC for access to additional modes:
· performing all kinds of measurements and displaying results on the PC screen
· viewing and editing data logs
· updating software and firmware
Specifications:
Frequency tuning range | 5 to 900 MHz |
Operating frequency range | 45 to 865 MHz |
Resolution | 125 kHz |
Ослабление встроенного аттенюатора | 20 дБ, 40 дБ |
Input mismatch attenuation
|
|
Level measurement range
|
|
Measurement level resolution | 0.1 dB |
Accuracy at tuning frequency | ±1.5 dB |
Accuracy at operating temperature | ±2.2 dB |
Measurement channel passband at -3 dB level | 230 kHz |
DVB-T demodulator parameters:
|
|
DVB-T2 demodulator parameters:
|
|
MER measurement range (DVB-T) | 18 to 35 dB |
MER measurement range (DVB-T2) | 15 to 35 dB |
MER measurement resolution | 0.1 dB |
MER measurement accuracy within 50-110 dBµV level range | ±2.0 dB |
BER measurement range (DVB-T)
|
|
BER measurement range (DVB-T2)
|
|
Frequency auto tuning step | ±0.5 MHz |
External devices power supply voltage | +12 V |
Warm-up time | 10 min |
Battery life under normal conditions (2100 mAh battery capacity) | 3 hours |
SAMPLE SCREEN VIEWS